Page 7-10 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
7.3 GIA 63 Integrated Avionics Unit
Original GIA 63(s) Reinstalled:
No software or configuration loading is required if the removed GIA is re-installed in its original position
(GIA1 and GIA2 in their original racks). This does not include units that were returned for repair as their
software and configuration files are deleted during the repair testing process. Continue to Section 7.3.2 if
the original unit with no repairs was reinstalled. Continue to Section 7.3.1 for repaired or exchanged units.
Original GIA 63s installed in opposite locations for troubleshooting:
No software loading is required if the originally installed GIA units are re-installed in opposite positions
(GIA1 and GIA2 in opposite unit racks). However, the units must be re-configured. Follow these
instructions to reconfigure the units without requiring the G1000 system software loader card:
1. With the system turned off, remove the GIA63 units and install in the opposite locations (i.e.
GIA1 into the GIA2 slot and vice versa).
2. Apply system power and place both PFD and MFD in Configuration Mode.
3. On the PFD, use the FMS knob to navigate to the GIA RS-232/ARNIC 429 CONFIG page.
4. In the SELECT UNIT box in the upper left corner of the screen, verify GIA1 is listed.
5. Press the SET>ACTV softkey in the lower left corner of the screen.
Figure 7-7. SET>ACTV Softkey
6. When the “Activate parameter settings?” window appears, verify OK is highlighted and press the
ENT key.
7. When the “GIA #1 Configured” window shows “Complete”, press the ENT key to select OK in
the window.
8. Activate the cursor, turn the small FMS knob to show the list of GIA choices in the SELECT
UNIT field, highlight GIA2 in the pop-up box and press the ENT key.
9. Press the SET>ACTV softkey in the lower left corner of the screen.
10. When the “Activate parameter settings?” window appears, verify OK is highlighted and press the
ENT key.