Cockpit Reference Guide for the Prodigy
®
Flight Deck 300
190-00761-01 Rev. A
128
Annunciations & Alerts
Flight
InstrumentsEAS
Nav/Com/
XPDR/AudioAFCSGPS Nav
Flight
PlanningProcedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
AlertsAppendixIndex
GWX 68 ALERT MESSAGES
Message Comments
GWX CONFIG
– GWX config error.
Config service req’d.
GWX 68 configuration settings do not match
those of the GDU configuration. The system
should be serviced.
GWX FAIL
– GWX is inoperative. The GDU is not recieving status packet from the
GWX 68 or the GWX 68 is reporting a fault.
The GWX 68 radar system should be serviced.
GWX SERVICE
– GWX needs
service. Return unit for repair.
A failure has been detected in the GWX 68. The
GWX 68 may still be usable.
MANIFEST
– GWX software
mismatch, communication halted.
The GWX 68 has incorrect software installed.
The system should be serviced.
WX ALERT
– Possible severe
weather ahead.
Possible severe weather detected within +/- 10
degrees of the aircraft heading at a range of 80
to 320 nm.
GCU 477 MESSAGE ADVISORIES
Message Comments
GCU CNFG
– GCU Config error.
Config service req’d.
GCU 477 configuration settings do not match
those of backup configuration memory. The
system should be serviced.
GCU FAIL
– GCU is inoperative. A failure has been detected in the GCU 477.
The GCU 477 is unavailable.
MANIFEST
– GCU software
mismatch, communication halted.
The GCU 477 has incorrect software installed.
The system should be serviced.
GCU KEYSTK
– GCU [key name]
Key is stuck.
A key is stuck on the GCU 477 bezel. Attempt
to free the stuck key by pressing it several times.
The system should be serviced if the problem
persists.